Medicol® ETO enables safe and effective ethylene oxide sterilization for medical devices that cannot tolerate heat or moisture. Its permeability, seal strength, and clean peel ensure both effective sterilization and safe opening.

Purpose-built for ETO sterilization

Reliable for sensitive devices

Medicol® ETO is tailored for ethylene oxide sterilization, providing high air permeability and strong seals so sterilant can penetrate effectively while maintaining a secure sterile barrier for temperature-sensitive medical devices.

Protection for delicate instruments

Safe for heat- and moisture-sensitive devices

Developed in close collaboration with healthcare providers, Medicol® ETO is ideal for devices that are prone to damage from heat or moisture, helping safeguard both packaging integrity and the sterile contents inside.

Strong, dependable barrier

High strength properties

Excellent tensile and burst strength help resist punctures and tears during processing, transport, and storage, maintaining the structural integrity of the sterile barrier throughout the device’s lifecycle.

Clean peel & easy opening

Safe access at point of use

Balanced seal strength and clean peel behaviour support safe, residue-free opening in the sterile field, helping reduce fibre tear and particle generation when packages are opened by clinical staff.

Explore Medicol® online

Full portfolio & documentation

Find detailed specifications, guidance and the complete Medicol® sterile barrier portfolio on the dedicated Medicol website — maintained with up-to-date technical and regulatory information.

Go to medicolpaper.com →
ISO 9001 — Quality Management

ISO 9001 ensures that our quality management system is structured, traceable, and continuously improving. It guarantees consistent product performance and reliable manufacturing processes from roll to roll.

ISO 14001 — Environmental Management

ISO 14001 certifies that our environmental management practices reduce ecological impact through controlled resource use, pollution prevention, and ongoing sustainability improvements.

ISO 45001 — Occupational Health & Safety

ISO 45001 confirms that our operations meet global standards for workplace safety, minimizing risks and creating a safe, well-controlled environment for all employees involved in production.

ISO 11607 — Packaging for Terminally Sterilized Devices

This certification verifies that Medicol® ETO meets the essential requirements for sterile barrier systems used for terminally sterilized medical devices, including performance in sterilization, transport, and storage.

NEN-EN 868-3 — Packaging Requirements & Test Methods

NEN-EN 868-3 specifies the material and performance requirements for sterilization packaging papers. It ensures key properties such as microbial barrier, strength, and porosity are validated through standardized testing.

NEN-EN 868-6 — Sterilization Packaging for Medical Devices

This standard defines additional test methods and requirements for sterile barrier paper used in medical device packaging, confirming durability, sealability, and compatibility with sterilization processes.

FSC® — Responsible Forest Management

FSC® certification ensures that all fibres used in Medicol® ETO come from responsibly managed forests, supporting biodiversity, sustainable forestry practices, and long-term environmental protection.

Medicol® ETO is manufactured under rigorous quality, safety and environmental controls, ensuring full compliance with the requirements for sterile barrier systems.

These certifications demonstrate our commitment to patient safety, consistent production, and responsible operations.

Closing the Water Loop

95% reused, 5% purified in our treatment plant

We reuse 95% of our process water and purify the remaining 5% in our own treatment plant before it returns to nature.

Solar-Powered Mobility

Electric fleet, charged by the sun

Our solar panels power a fully electric fleet of company cars, cutting emissions from day-to-day operations.

Community Heat Recovery

Sharing residual heat locally

Leftover production heat is recovered and used to warm nearby facilities, providing sustainable comfort to our community.

Clean Process Heat

eBoiler powered by electricity

A new eBoiler replaces fossil fuel heat with clean electric energy to run our production process.

Technical specifications

Medicol® ETO Sterile Barrier Paper
Best forETO sterilization of heat- and moisture-sensitive devices; also suitable for irradiation.
GrammageAvailable in 60, 68, 80 & 100 GSM.
BarrierReliable microbial barrier for safe sterilization and storage.
StrengthHigh tear and burst resistance for secure packaging.
Seal & PeelStrong seals with smooth, residue-free opening.
HandlingStable performance on standard medical packaging lines.
SustainabilityOver 99% biobased, fully recyclable, FSC® fibers.
Request quote
Recommended sterilization & sealing
Shelf life & handling
Converting & Process

Frequently Asked Questions (FAQ)

Clear answers to the most common questions about our papers and processes. Can’t find what you need? Send us your question and we’ll help right away.

What is Medicol® ETO used for?

Medicol® ETO is designed for medical devices that cannot withstand high temperatures or moisture, making it ideal for ethylene oxide sterilization.

What makes Medicol® ETO different from other sterile barrier papers?

It combines high air permeability with strong seal integrity and clean peel performance, ensuring both sterilization effectiveness and safe opening.

Is the paper sustainably produced?

Yes. All Medicol® papers use FSC®-certified fibers and are produced in a facility that reuses 95% of its water, recovers residual heat, and invests in renewable energy solutions such as solar and an electric e-boiler.

Where can I find full specifications?

Visit medicolpaper.com/products/medicol-eto/ for the complete documentation.

Can I request samples?

Yes — use the form below and our team will assist you.

Request a sample, quote or TDS

Not sure which grammage or format fits your packaging process?

Tell us about your sterilization method and device requirements — we’ll help you choose the right Medicol® paper for your workflow.






    By using this form you agree with the processing of your data by this site as described in our Privacy Policy. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.